ibidi Pump System

Model:10902

Brand:ibidi

Specifications

Introduction:A pump system for the cultivation of, e.g. endothelial, cells under flow for simulation of blood vessels

*Defined shear stress in long-term culture (e.g., endothelial cells, kidney, or biofilm)

*Live cell imaging and immunofluorescence for analyzing shear stress response

*Mimicking shear stress conditions in microcapillary, venous, and arterial flow

*Rolling and adhesion of suspended cells on substrates

*3D cell culture: interstitial flow

Technical Features:

Operates up to four parallel Fluidic Units per ibidi Pump

Flow characteristics: all flow types are laminar

Some examples:

Unidirectional flow simulates veins or small arteries

Oscillating flow simulates disturbed conditions at vessel branchings or valves

Pulsatile flow simulates arterial conditions

Wide range of flow rates (ca. 0.1–50 ml/min*) and shear stress (ca. 0.1–200 dyn/cm2*)

Working volume: 2.5 ml / 12 ml / 50 ml

Suitable for all μ-Slides with Luer adapters

Also suitable for home-made flow chambers

Compatible with all incubators

Software-controlled flow rates and shear stress

* Depending on the Perfusion Set and Channel used.

System Overview:

The ibidi Perfusion System Perfectly Reflects the Natural Environment of Cells Under Flow Conditions

The ibidi Pump System consists of two main components: The ibidi Pump (computer controlled air pump, placed outside the incubator) and the Fluidic Unit (holder for cell media reservoirs and μ-Slide, tubing, and electrically controlled valve set, placed inside the incubator). By using this "split" approach, the closed circulation of the medium can be assembled separately in the laminar flow hood and transferred to the microscope or the incubator, without compromising the sterility of the system. The open architecture using the Luer connectors allows the use of any kind of flow devices. The PumpControl software controls the pressure, and subsequently the shear stress acting on the cells, and provides the possibility to program complex flow patterns.

Placing the Fluidic Unit inside a large-size microscope incubator allows for running long-term perfusion assays directly on the microscope. A defined temperature and CO2 concentration is assured over the whole perfusion, which is necessary for avoiding air bubbles. For short-term experiments, the usage of a small incubator, hosting the Fluidic Unit, next to the microscope is sufficient.

Principle of Unidirectional Flow

Applying pressured air to the reservoirs of the Fluidic Unit moves the medium and generates the flow in the μ-Slide channels. In order to avoid wasting any medium, the liquid is pumped back and forth between reservoir A and reservoir B by switching the valve V1.

To assure a unidirectional flow in the channel, the other valve V2 is switched simultaneously. As the tubing parts inserted in the valve V2 are criss-crossed, the medium is always directed to the same end of the channel slide.


Related Products
Inquiry message
*Name:

*Company/City:
*Phone:
*Contact:
*City:
*Code:
主站蜘蛛池模板: 成人免费视频在线观看| 嫩小xxxxbbbb| 国产女合集小岁9三部| 制服丝袜小说| 天天干天天操天天玩| 亚洲日本欧美| 五月婷婷在线观看| 日韩亚洲欧洲在线com91tv| 一级做a爰片久久毛片免费| 久久超碰国产精品最新| 福利片午夜| 日日a.v拍夜夜添久久免费| 亚洲最大成人| 国产精品亚洲国产三区| 息孑性教育中文字幕影音先锋| 欧美日韩一二区旡码高清在线| 亚洲欧美日韩高清中文在线| 免费亚洲视频在线观看| 午夜福利免费0948视频| 亚洲伊人色综合久久天天伊人| 亚洲青青青网伊人精品| 日本乱中文字幕系列在线观看| 手机亚洲第1页| 欧美在线 在线播放| 性色少妇AV蜜臀人妻无码| 日韩精品视频观看| 久久99国产亚洲高清观着| 色免费视频| 色婷婷色婷婷| 激情床戏视频片段有叫声| 日韩一级精品视频在线观看| 小嫩模无套内谢第一次| 日本一本在线视频| 在教室伦流澡到高潮H免费视频| 天堂va亚洲va欧美va国产| 亚州1区2区3区4区产品乱码2021| 我和黑帮老大第365天第2季在线| 性欧美黑人巨大喷潮xxoo| 四虎必出精品亚洲高清| 久久66热在线视频精品| 日本 国产 欧美|